Electrical Connection; Regulations For Electrical Connection; Establish An Electrical Connection - Rational UltraVent XS Manual De Instalación Original

Ocultar thumbs Ver también para UltraVent XS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
en

5.2 Electrical connection

DANGER
High voltages when connecting to the
mains power
Danger to life due to high voltage.
Disconnect from the power supply.
n
Make sure the unit is disconnected
n
from the power.
DANGER
Electric shock from incorrect
connection
There is a danger to life if the wires are
incorrectly connected.
Connect the wires correctly as
described according to their colour
coding.
5.2.1 Regulations for electrical
connection
General information
The UltraVent condensation hood be
n
connected to an electrical supply in line
with standards in your country.
Before you disconnect the unit from
n
the mains or reconnect it to the mains,
make sure that the unit is switched off
to prevent the UltraVent condensation
hood from running.
The condensation hood must be fused
n
with a maximum of 16 A by the cus-
tomer.
Notes on the connection cable
The condensation hood must be
n
equipped with a power cable approx-
imately 2 metres long.
16 / 112
n
n
n

5.2.2 Establish an electrical connection

a
a
a
1. Open the left side panel of the unit
2. Release the attachment of the safety
3. Break loose the back panel of the elec-
4. Slide the bus cable and the shielding
5. Connect the control cable to a free bus
6. Fix the cable to the rear of the unit
7. Connect the shielding cable to the
8. Close the left side panel.
>>
80.51.574_iCombi Pro-iCombi Classic_UV XS_IM_V01_EU-west
A separate power plug must be in-
stalled.
If the connection cable needs to be re-
placed, use a H05 RN-F 3 x 1.5 mm
quality cable.
The mains power cable may only be
replaced by qualified personnel au-
thorised by the manufacturer.
The unit on which the condensation
hood is to be installed is disconnected
from the mains.
The control board is located on the
back of the UltraVent.
A bus cable is plugged into the control
board. A further PG connection is at-
tached to the bus cable.
[
Photo
16].
temperature limiter. Place it to one
side [
Photo
17].
trical compartment.
cable through the hole. Attach the PG
connection.
interface of the fan motor
[
Photo
18].
with the supplied cable support.
earth connection on the housing of the
steam generator [
The electrical installation of the Ultra-
Vent is completed.
5 | Installation
2
Photo
19].

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ultravent plus xs

Tabla de contenido