16 Datos específicos de DeviceNet
Class
Inst.
Derechos de
acceso
Fh
15h
Get
Fh
16h
Get
Fh
17h
Get
Fh
18h
Get
Fh
19h
Get
Fh
1Ah
Get
Fh
1Bh
Get/Set
Fh
1Ch
Get
GEMÜ 4242
Attr.
Parámetro
1h
Valve position
1h
Sensor error
1h
Programing error
1h
Pneumatic error
1h
Internal error
1h
Stroke reduction war-
ning
1h
Valve cycles user
1h
Valve cycles total
Longi-
Tipo de
tud
datos
2 bytes UINT
0
1 byte USINT
0
1 byte USINT
1
1 byte USINT
0
1 byte USINT
0
1 byte USINT
0
4 bytes UDINT
0
4 bytes UDINT
0
42 / 46
Ajuste de
Posibilidades de ajuste
fábrica
0 = Sensor OK
1 = Sensor error position
closed
2 = Sensor error position
open
0 = Programming OK
1 = not calibrated
2 = no stroke
3 = stroke < min. stroke
4 = Sensor error position
closed
5 = Sensor error position
open
6 = Sensor error position
closed + open
0 = Pneumatic OK
1 = Pneumatic error posi-
tion
closed
2 = Pneumatic error posi-
tion open
3 = Pneumatic error middle
position
0 = Device OK
1 = un-valid crc-check
2 = un-valid serial number
3 = Memory error
0 = Stroke OK
1 = Stroke reduction posi-
tion
closed
2 = Stroke reduction posi-
tion open
3 = Stroke reduction posi-
tion
closed + open
Se puede restablecer a 0,
indicación de valores nu-
méricos
0–429496729
Indicación de valores nu-
méricos
0–429496729
www.gemu-group.com