CABLE SUBSTITUTION
This must be carried out by a qualified authorised technician. The earth wire must always be yellow
green.
WARNING: the yellow/green voltage wires in the earth cable must be 3cm longer than the others.
Proceed as follows to connect the power supply wire to the terminal board:
•
( A1 ) Loosen the tops of the cable gland and open the bottom part of the back of the appliance by
loosening the screws.
( A3 ) Loosen the terminal screws and feed the cable conductors through. Take out the old cable from
•
the cable gland.
( A2 ) Feed the new cable through the cable gland. Connect the new cable's conductors to the terminal
•
following the connection diagram on the label at the lower part of the back of the appliance. Only
connect what is indicated inserting the copper bridge and the electricity cable together under the
screws, in the tightening direction, so the cable and the bridge are tightly fixed by tightening the screw.