Selecting The Display Language; Setting The Clock; Setting The Buzzer Volume; Understanding The "Recording" Sub-Menu - HURNER Weld Control 315 2.0 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
dard (guideline, normative scheme) applicable to the
welding operation.
4.1.3

Selecting the Display Language

When the "Language" sub-menu was selected, the screen
changes and the display reproduced in Display 7 appears.
Use the arrow keys ñ and ò to select one of the options,
"Deutsch," "English," "Français," etc. and confirm by press-
ing the START/SET key.
4.1.4

Setting the Clock

When the "Date/Time" sub-menu was selected, the screen
changes and the display reproduced in Display 8 appears.
The time of day and the date can be set using the key-
pad. The portions "Hour," "Minute," "Day," "Month," and
"Year" are set separately. Press the START/SET key to con-
firm your settings.
4.1.5

Setting the Buzzer Volume

When the "Buzzer Volume" sub-menu was selected, the
screen moves on to what is reproduced in Display 9. The
buzzer can also be heard. Turn the buzzer up or down to the
desired value using the ï, ð cursor keys (from 0 to 100) and
confirm your setting by pressing the START/SET key.
4.1.6

Understanding the "Recording" Sub-menu

"Welder Code on" means that the welder identification
code has to be entered as set with "Welder Code Op-
tions," under "Settings," "off," that this is impossible.
"Commission Number on" means that the commission num-
ber (job number) will have to be entered or confirmed
before every new welding, "off" that the user is not
prompted to enter it.
"Joint Number on" means that the systems assigns an au-
tomatically incremented joint number to every welding
operation belonging to a commission already known,
and displays this number on the screen next to the re-
port number, "off" that no joint numbers will be as-
signed at all.
"Additional Data on" means that the additional data will
have to be entered or confirmed before every new weld-
ing, "off" that the user is not prompted to enter them.
"Fitting Code on" means that the second, so-called trace-
ability code of the pipeline fitting that is going to be
worked has to be entered before every welding, "off,"
that this is not possible.
"Pipe Codes on" means that the codes of both pipes/compo-
nents (ISO-compliant welding and treaceability codes)
have to be entered before every welding, "off," that
this is not possible.
Version May 2022
HÜRNER Weld Control 315 2.0 User's Manual
***** LANGUAGE *****
>Deutsch
English
Francais
Display 7
Date/Time
21.06.13
14:28
Display 8
Buzzer Volume
< ------20-------- >
Display 9
CONFIGURATION **
**
>Welder Code
On
Commission No.
On
Joint No.
Off
Display 10
EN
17

Publicidad

Tabla de contenido
loading