S Ystem O Peration - Amana ASXS61A Serie Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SUBCOOLING = (SAT. LIQUID TEMP.) - (LIQUID LINE
TEMP.)
Charging Table
OD Ambient Temp
< 65°F
(degF)
1.5 ton
2.0 ton
2.5 ton
Subcooling
Weigh in
3.0 ton
(degF)
Charge
3.5 ton
4.0 ton
5.0 ton
Note: Subcooling information is valid only while "cha" and current subcool-
ing value is being displayed alternately on PCB.
NOTE: Not more than 8 oz. of refrigerant be added to the
system to achieve the target subcooling. It is recommended
adding 1 oz. refrigerant each time, then wait 10 minutes to
stabilize the system.
NOTICE
C
S
heCk the
Chrader portS for leakS and tighten valve CoreS
. i
neCeSSary
nStall CapS finger
NOTICE
d
not
o
adjuSt the Charge baSed on SuCtion preSSure
SATURATED LIQUID
PRESSURE TEMPERATURE
CHART
LIQUID
R-410A
PRESSURE
°F
PSIG
200
70
205
72
210
73
215
75
220
76
225
77
230
79
235
80
240
81
245
83
250
84
255
85
260
87
265
88
270
89
275
90
280
91
285
92
290
94
295
95
300
96
305
97
65°F to 105°F
ASXS60 ASXS6S ASZS60
10 ± 1°F 10 ± 1°F 10 ± 1°F
12 ± 1°F 12 ± 1°F 12 ± 1°F
14 ± 1°F 14 ± 1°F 14 ± 1°F
13 ± 1°F 15 ± 1°F 15 ± 1°F
-
8 ± 1°F
8 ± 1°F
-
9 ± 1°F
9 ± 1°F
-
9 ± 1°F
9 ± 1°F
-
.
tight
.
SATURATED LIQUID
PRESSURE TEMPERATURE
CHART
LIQUID
R-410A
PRESSURE
°F
PSIG
310
98
320
100
330
102
340
105
350
107
360
109
370
111
380
113
390
115
400
117
410
118
420
120
430
122
440
124
450
126
460
127
470
129
480
131
490
133
500
134
510
136
520
137
S
O
yStem
peratiOn
S
yStem advanCed featureS
This system permits access to additional system informa-
> 105°F
tion, advanced set-up features, and advanced diagnostic/
troubleshooting features.
These advanced features are organized into a menu struc-
ture.
Weigh in
Charge
For detailed functions and menu layout, please visit the
Amana Smart Thermostat website at
https://www.amana-hac.com/products/controls/touchscreen-
thermostats
C
ooling booSt mode
COOLING BOOST MODE enables the system to operate
at increased compressor speeds in cooling mode to satisfy
unusual high loads. COOLING BOOST MODE is initiated by
an outdoor temperature sensor located in the outdoor unit.
Please note that outdoor equipment operational sound levels
may increase while the equipment is running in COOLING
,
if
BOOST MODE since compressor speed higher than normal
operation is allowed.
NOTE: COOLING BOOST MODE is ON by default and is
activated when the outdoor temperature reaches 100°F.
COOLING BOOST MODE can be disabled and enabled
and the activation temperature adjusted in "COOLING
BOOST MODE Temperature"
h
eating booSt mode
HEATING BOOST MODE enables the system to operate at
increased compressor speed while in heating mode, regard-
less of outdoor ambient temperature. However, maximum
compressor speeds only appear in low ambient temperature
operation if HEATING BOOST MODE is disabled.
b
aCkup defroSt
(
hp model only
This mode enables the system to select heating operation
during defrost. When this mode is ON, 2nd heating source
(Electric Heater or Gas Furnace) is turned on during
defrost. This mode is initiated by an outdoor temperature
sensor located in the outdoor unit. This mode is activated
when the outdoor temperature reaches set point. Also
"Always ON" and "OFF" are available.
m
aximum defroSt interval
This setting enables the system to change timer defrost
interval. In the case system needs to have defrost operation
more frequently, defrost interval can be changed. The initial
setting is 120 min.
28
28
ASXS6S̲3P679063-2D̲ALL̲220729.pdf
(
)
hp model only
(
)
defroSt heat
mode
)