Before Starting The Tool; Starting And Stopping; Failure To Start - Rupes HQM83 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model
Chemistry
9HB125LT
Lithium Ion
WARNING: charge Rupes Li-ION Battery pack 9HB125LT only in the Rupes Li-ION Battery Charger
9HC120LT. Other types of batteries may cause personal injury and damage.
This tool's battery pack and charger are not compatible with NiCd or NiMH systems.
When to charge
Charge your battery tool when convenient for you and your job. The Rupes Q-MAG NANO iBrid tool Battery pack
does not develop "memory" when charged after only a partial discharge. It is not necessary to run down the battery
tool pack before placing it on the charger. Use the led Battery pack 9HB125LT level indication on the Rupes
Q-MAG NANO iBrid tool HQM83/HQM83L to determine when to charge the Rupes Battery pack.
Charge the battery pack 9HB125LT
The battery pack(s) contained in the kit shall be charger before use. The provided battery is charged <30%. In
order to charge connect the Li-ion battery with a charging station 9HC120LT till the charging is completed.
WARNING
For your personal safety, READ and UNDERSTAND the instruction manual of charging station
9HC120LT before using.
Assemble battery pack 9HB125LT
WARNING: Before (dis)assembling the tool assure that the speed regulation Knob (2) is in OFF
position.
In order to assemble the battery pack push two clips (Fig. 7) at the same time and insert the battery pack in the
tool till it is fi xed.
In order to disassemble push two clips at the same time and extract the battery from a tool (Fig. 8).
POWER SUPPLY (provided or optional)
WARNING
For your personal safety, READ and UNDERSTAND the instruction manual of Power supply
9HP120LT before using.
Assemble power supply 9HP120LT (10)
WARNING: Before (dis)assembling the tool assure that the speed regulation Knob (2) is in OFF
position.
In order to assemble the power supply block push two clips (Fig. 9) at the same time and insert the power supply
block in the tool till it is fi xed. In order to disassemble push two clips at the same time and extract the power supply
block from a tool (Fig. 10)

BEFORE STARTING THE TOOL

Ensure that :
- the electric system conforms with the characteristics indicated on a label and the power supply cable and plug
are in perfect condition (when the tool is used with a battery pack 9HP120LT)
- the battery pack is in a perfect condition and is charged (see Battery pack level indication)
- the ON/OFF switch works properly with the power supply 9HP120LT/battery pack 9HB125LT disconnected;
- all the parts of the tool have been assembled in the proper manner and that there are no signs of damage;
- the ventilation slots are not obstructed.

STARTING AND STOPPING

- Starting: rotate the potentiometer knob (2) and set up the speed from 1 to 5 value. Push the switch lever (7)
towards the body of the tool.
- Stopping: release the lever and rotate the potentiometer knob until OFF position.
WARNING: if a case of unusual vibration, or dismatching of the backing pad is present after a start
of the tool, switch-off the tool immediately and eliminate the fault.

FAILURE TO START

If a tool is failed to start, in a case of:
10
Voltage (V)
Capacity (Ah)
10.8
2,5
Energy (Wh)
Weight (kg)
27÷27,75
0.183 ±0.005