PARTS OF THE TOOL
1 - Identification plate
2 - Compressed air on/off lever
3 - Speed control
4 - Tool body
5 - Compressed air connection with 1/4" thread
Suction cowling
6 -
7 - Routed exhaust air terminal
8 - Velcroed abrasive disc backing pad
9 - Spanner
10 - Dust extraction flow control
STARTING UP
Before starting-up the tool, ensure that:
- the packaging is complete and does not show signs of having been
damaged during storage or transport;
- the tool is complete; check that the number and type of components com-
ply with that reported in this instruction booklet;
- the available compressed air production and distribution plant is ca-
pable of satisfying the requirements reported on the tool's identifica-
tion plate reproduced and explained on page 11.
ASSEMBLING THE TOOL
Assemble the compressed air connection (non supplied) by screwing
it into its seating (5).

COMPRESSED AIR CONNECTION

The tool is supplied without the compressed air connection; the user
can use either a quick release coupling or hose type connection
according to his needs, purke they have an hole of air passing mm. 8.
In the latter case the air line must be fixed to the nozzle by a hose clip.
DISC PAD ASSEMBLY AND REMOVAL
- Turn command (3) to "OFF";
- insert the key (9) and hold the shaft in place, manually screw on the
pad (8) and make sure it is screwed on completely;
- to remove, insert the key (9), hold the shaft in place and unscrew
the pad (8).
FITTING ABRASIVE PAPER DISCS
- Turn command (3) to "OFF";
- press the abrasive disc into the pad ensuring that the holes in the
paper.
BEFORE STARTING THE TOOL
Ensure that:
- the speed control (3) is in MAX position;
- the compressed air feed line and connection are in perfect working
order;
- the start lever is working properly. This must be done with the air
supply switched off;
- all the components of the tool are mounted correctly and do not
show any signs of damage.
STARTING AND STOPPING
Starting: push the control lever (2) forward towards the body of the
tool and keep it pressed.
Stopping: release the control lever.
TEST RUN
Start the tool and check that there are no unusual vibration.
Otherwise switch-off the tool immediately and eliminate the
cause by an authorized customer-service workshop.