AEG L 82470 BI Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

20
www.aeg.com
4. Release the emergency emptying hose,
place it in the container and remove its cap
cover.
5. When no more water comes out, unscrew
the filter cover by turning it anti-clockwise
and remove the filter. Use pliers, if necessary.
1
Always keep a rag nearby to dry up any water
spillages when removing the cover. Clean the
filter under a tap, to remove any traces of
2
fluff.
6. Remove foreign bodies and fluff from the
filter seat and from the filter impeller.
7. Check carefully whether the pump impeller
rotates (it rotates jerkily). If it doesn't rotate,
please contact your Service Centre.
8. Put the cap back on the emergency
emptying hose and place the latter back in its
seat. Replace the filter into the pump by
2
inserting it correctly into the special guides.
Screw the filter cover firmly by turning it
clockwise.
1

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido