Coelbo ECODRIVE Instrucciones Para La Instalación Y Utilización página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4. MAIN CHARACTERISTICS.
• Inlet port G1" male ISO 228.
• Outlet port G1" male ISO 228.
• Frequency inverter for the pump control.
• Control and safety system against over-intensities.
• Control and safety system against dry operation.
• ART function (Automatic Reset Test). If the device has been stopped due to the action of the safety sys-
tem against over-intensities, the ART tries to connect the pump, with a programmed periodicity because
the water supply could have been restored
• Automatic restore system after an interruption of power supply. System is activated in AUTOMATIC mode
keeping the configurationparameters (see chapter 10).
• Inner pressure transducer with digital indicator,
• Inner current sensor with instantaneus digital reading.
• Control panel (see chapter 8): 2 digits display, pushbuttons, led lights and digital gauge providing instan-
taneous lecture of pressure.
• Register of operational controls: infomation about operating hours, counter of starts, counter of connec-
tions to the power supply.
• Register of alarms: information about type and number of alarms since the starting up of the device.
5. TECHNICAL CHARACTERISTICS.
• Power supply voltage
• Frequency
• Max. current each phase
• Max. peak of current
• Max. operating pressure
• Max. set pressure
• Protection index
• Max. water temperature
• Max. environment temperature
• Max. flow
6. HYDRAULIC CONNECTIONS (FIG.3)
Before proceeding with hydraulic connection it is essential to install a non-return valve in the pump´s inlet
or outlet.
The device must be connected in vertical position (FIG.3), the inlet port ( G1" male) directly to the main pump
discharge and the outlet port (G 1" male) at the main network.
It is compulsory to use an hydropneumatic tank in order to avoid continuous start-stops due to the deterio-
ration of taps, valves, ... and also to prevent "water hammer" in installations with valves of wide diameter.
7. ELECTRIC CONNECTION (FIG.1 - FIG.2)
Before doing manipulations inside the device, it must be disconnected of the electric supply and after disa-
bling, wait for 2 minutes in order to avoid electrical discharges.
Use cables type H07RN-F with section enough to the power installed:
• Power supply: s ≥ 1,0 mm²(max.2,5 mm²).
• Motor supply: s ≥ 1 mm² (max.2,5 mm²) depending on the cable length (FIG.2).
Verify if the power supply is 127-230 V. Dismount the front cover and carry out the connections according to
the indications of FIG.1.
Do the power supply connection (being sure there is a good earth connection): N
Do the connection by mean of magnetothermic switch in OFF mode.
The earth conductor must be longer than the others. It will be the first one to be mounted during the as-
sembly and the last one The earth conductor must be longer than the others. It will be the first one to be
mounted during the assembly and the last one to disconnect during disassembling.
Do the pump connection: V W
WARNING! Wrong connections could spoil the electronic circuit. The manufacturer declines all responsa-
bility in damages caused by wrong connection.
1x127-230~V +10% -20% V
50/60 Hz
7.5A
10% during 10"
15 bar
0.5÷8 bar
IP55
40ºC
0-50ºC
8.000 l/h
.
7
Video Youtube
L

Publicidad

Tabla de contenido
loading

Tabla de contenido