Location Requirements

Product dimensions
B
A
I* - Metallic spacers
Spacers has to be
installed and used
when cabinet depth
is greater than 12".
A
B
C
D
E
F
G
H
I
For gas range installation: Mount this hood so that the bottom
edge is at minimum 30"(76.2 cm) above the cooking surface.
For electric range installation: mount this hood so that the
bottom is not less than 24"(61 cm).

Venting Requirements

Vent system must terminate to the outdoors, except for no
vented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Rigid metal vent is recommended. Plastic or metal foil
vent is not recommended. The length of vent system and
number of elbows should be kept to a minimum to provide
efficient performance.
H
G
F
E
I*
D
C
I*
Model
EUM634SS
34
" (86.7 cm)
9
6 4
26" (66 cm)
41⁄ 1 6" (10.3 cm)
103⁄ 4 " (27.3 cm)
1045⁄64" (27.2 cm)
03⁄ 8 " (.95 cm)
153⁄ 4 " (40 cm)
6" (15.2 cm)
1⁄2" (1.27 cm)
Installation clearances
C
E
F
3⁄16
A. 13
" (33.5 cm) min. upper cabinet
height
B. 35
/
" (89.7 cm) cabinet opening
5
16
width
C. 24" (61 cm) minimum fromthe
electric cooking surface, and 30"
(76.2 cm) on a gas stove. 36" (91.4
cm) maximum suggested from the
base of the cabinet to the cooking
surface.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper.
Use caulking to seal exterior wall or roof opening around
the cap.
The size of the vent should be uniform.
A
B
D
D. 12
/
" (31 cm) minimum cabinet
13
64
opening depth
E. 15" (38.1 cm) min. clearance upper
cabinet to countertop
F. 36" (91.4 cm) base cabinet height