• Before making cutouts, make sure there is proper clearance
within the ceiling or wall for the exhaust vent.
• When cutting or drilling into the ceiling or wall, do not
damage electrical wiring or other hidden utilities.
• Check that all installation parts have been removed from
the shipping carton.
NOTE: For the correct performance of your In-Line Blower
System you must remove the Range Hood Internal Motor
Blower.
Remove Range Hood Internal Motor Blower
1
Remove grease filters from range hood.
2 Disconnect the blower power cord from de wire box.
A
B
A. Wire box connector
B. Power cord
3 For EAR134S4, EAR140S4, EAR146S4, ECL136S4,
ECL142S4, ECL148S4, ETR134S1 and ETR146SS range
hood models you have to remove the 4 - 6 x 16 mm screws
holding the blower motor.

Prepare location

4 For ELN136S2, ELN142S2, ELN148SS, ELI136S2 and
ELI142S2 models remove duct covers and the 4 - 6 x 16
mm blower motor screws
5 Remove the motor mounting plate by setting free the
spring clip.
NOTE: The spring clip should be outside the slot in the
mounting plate.
A
B
A. Mounting plate
B. Spring Clip
A
A. Mounting plate
B. Spring Clip
B