Installation Instructions; Prepare Location - ELICA KIT0179549 Guía De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

Before making cutouts, make sure there is proper
clearance within the ceiling or wall for the exhaust vent.
When cutting or drilling into the ceiling or wall, do not
damage electrical wiring or other hidden utilities.
Check that all installation parts have been removed from
the shipping carton.
NOTE: For the correct performance of your In-Line Blower
System you must remove the Range Hood Internal Motor
Blower.
Remove Range Hood Internal Motor Blower
1
Remove grease filters from range hood.
2 Disconnect the blower power cord from de wire box.
A
B
A. Wire box connector
B. Power cord
3 For EAR134S4, EAR140S4, EAR146S4, ECL136S4,
ECL142S4, ECL148S4, ETR134S1 and ETR146SS range
hood models you have to remove the 4 - 6 x 16 mm screws
holding the blower motor.

Prepare location

4 For ELN136S2, ELN142S2, ELN148SS, ELI136S2 and
ELI142S2 models remove duct covers and the 4 - 6 x 16
mm blower motor screws.
5 Remove the motor mounting plate by setting free the
spring clip.
NOTE: The spring clip should be outside the slot in the
mounting plate.
A
B
A. Mounting plate
B. Spring Clip
A
A. Mounting plate
B. Spring Clip
B
7