Location Requirements; Product Dimensions; Installation Clearances; Venting Requirements - ELICA ESN130 Guía De Instrucciones Para Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION REQUIREMENTS

IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsability to comply with
installation clearances specified on the model/serial rating
plate. The model/serial rating plate is located inside the
range hood on the left wall.
Range hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be
used. Given dimensions provide minimum clearance
Consult the cooktop/range manufacturer installation
instructions before making any cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
All openings in ceiling and wall where range hood will be
installed must be sealed.
These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the
"Accessories" section to order recirculation kit.

Product Dimensions

"
(2.2 cm)
4
"
(12.5 cm)
"
(2.2 cm)
29
" (76.0 cm) or
35
" (91.0 cm)
6
" (16.7 cm)
1"
(2.5 cm)
9"
(22.9 cm)
1 "
18 "
(3.81 cm)
(47.3 cm)

Installation Clearances

B
A
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop
B. 18" (45.7 cm) to 24" (61.0 cm) suggested max. - bottom of range
hood to cooking surface
C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm)
models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm)
models.
D. 13" (33.0 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height

VENTING REQUIREMENTS

Vent system must terminate to the outdoors, except for no
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 7" (17.8 cm) round metal vent or a 3¹⁄
25.4 cm) rectangular metal vent, depending on your model.
Rigid metal vent is recommended. Plastic or metal foil vent is
not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
4
C
D
E
" x 10" (8.3 x
4

Publicidad

Tabla de contenido
loading

Tabla de contenido