Descargar Imprimir esta página

Kärcher IVM 40/12-1 M Z22 Manual De Instrucciones página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
7. Dispose of the dust bag in accordance
with statutory regulations.
WARNING
Improper handling when locking the dirt
receptacle
Risk of crushing
Under no circumstances should you hold
your hands between the dirt receptacle and
filter ring or allow them to come close to the
lifting mechanism while locking it.
Lock the dirt receptacle by operating the
bow handle with both hands.
Illustration E
ATTENTION
Static charge of the dirt receptacle
Ignition of dusts
Make sure that the grounding on the chas-
sis is in contact with the dirt receptacle.
8. Fit the dirt receptacle and lock it with the
bow handle.
Switching on the device
1. Plug the mains plug into the socket.
2. Switch on the device at the suction tur-
bine power switch.
3. Start vacuuming.
Performing the vacuuming process
1. Regularly check the filling level in the dirt
receptacle, since the device does not
switch off automatically.
2. If necessary, empty the dirt receptacle
(see chapter Emptying the dirt recepta-
cle).
3. If necessary, clean the filter (see chapter
Dedusting the filter) or change/
replace the filter (see chapter Replacing
the filter).
Reading the minimum volumetric
A pressure gauge showing the vacuum in-
side the device is mounted on the front of
the device. The filter must be cleaned when
the maximum vacuum (see table) is
reached (see chapter Dedusting the filter).
This value depends on the device perfor-
mance and the suction hose used. If the
vacuum is not significantly reduced by de-
dusting, the filter must be replaced (see
chapter Replacing the filter).
20
flow
ATTENTION
Exceeding the maximum vacuum
Suction loss
If the specified value is exceeded, the air
speed in the suction hose drops below
20 m/s. Clean or replace the filter.
Nominal width of
the suction hose
DN40
DN50
Dedusting the filter
The filter must be cleaned if the pressure
gauge shows the maximum vacuum (see
chapter Reading the minimum volumetric
flow).
Illustration G
1. Close the inlet opening or the suction
hose during the suction process.
2. Pull the flap of the filter dedusting sys-
tem 3-4 times and hold it open for 1-
2 seconds each time.
Switching off the device
1. Switch off the device at the suction tur-
bine power switch.
2. Pull out the mains plug.
Each time after use
Emptying the dirt receptacle
The dirt receptacle must be emptied as
necessary and after each use.
The inlet opening or the suction hose are
closed.
1. Switch on the device at the suction tur-
bine power switch.
2. Dedust the filter (see chapter Dedusting
the filter).
3. Switch off the device at the suction tur-
bine power switch.
4. Secure the device with the parking
brakes.
Illustration B
5. Pull the bow handle up.
The dirt receptacle is unlocked and low-
ered.
Illustration C
6. Pull the dirt receptacle out of the device
by the bow handle.
English
Maximum vacuum
12.0 kPa (120 mbar)
7.0 kPa (70 mbar)

Publicidad