Hanging the Fan
to turn off the power. Follow
REMEMBER
the steps below to hang your fan properly.
NOTE: This fan is recommended for
standard ceiling mount using the downrod
provided with this fan. When using standard
ceiling installation with the 4.25 inch
downrod provided, the distance from the
ceiling to the bottom of the fan blades will be
approximately 10.4 inches.
Standard Ceiling Mounting
1. Remove the mounting bracket from the
canopy by loosening the four screws on
the top of the canopy. Remove the two
non-slotted screws and loosen the slotted
screws. This will enable you to remove the
mounting bracket. (Figure 5)
2. Remove the hanger pin and locking pin from
downrod assembly.
3. Make sure the slot openings are on top.
Route the wires through the canopy and then
through the ball/downrod assembly. (Figure
6)
4. Loosen, but do not remove, the set screws
on the collar on the top of the motor
housing.
5. Align the holes at the bottom of the downrod
with the holes in the collar on top of the
motor housing. (Figure 6)
Carefully insert the hanger pin through the
holes in the collar and downrod. Be careful
not to jam the hanger pin against the wiring
inside the downrod. Insert the locking pin
through the hole near the end of the bolt until
it snaps into its locked position, as noted in
the circle inset of Figure 6.
6. Re-tighten the set screws on the collar on top
of the motor housing.
7. Make sure that the canopy is oriented
correctly.
8. Proceed to "Installing the Fan" section.
FAILURE TO PROPERLY INSTALL SET SCREWS
AS NOTED IN STEP 6 COULD RESULT IN FAN
LOOSENING AND POSSIBLY FALLING.
Loosen but Do Not Remove
Remove
Motor wires
Slot opening
Ball/Downrod
assembly
Canopy
Hanger Pin
Tighten
Motor
screws
Collar
Figure 5
Pin in locked
position
Locking Pin
Figure 6