Descargar Imprimir esta página

Kärcher IVS 100/40 M Manual Del Usuario página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
Close the suction connection
WARNING
Health risk on account of fine dust! If the suction hose is
removed, the suction connection must be closed.
 Properly insert the connection socket in the suction
connection.
 Push in the connection socket until it locks into
place.
 Turn the suction connection with the connection
socket to the right to close it tightly.
Wet vacuum cleaning
Caution: Constantly monitor the fill level in the dirt
receptacle when vacuuming high volumes of liquid,
as the receptacle can be filled within a matter of sec-
onds and could overflow.
DANGER
No dusts hazardous to health should be sucked in dur-
ing wet vacuuming.
To suck wet dirt, always remove the disposal bag.
Changeover from wet to dry vacuum
ATTENTION
Please note the following when switching from wet
to dry vacuum cleaning:
WARNING
Health hazard due to fine dust. If the device has been
used for wet vacuum cleaning, then the filter must be re-
placed. Filters that have become wet no longer fulfil the
requirements for dusts that are harmful to health and
may no longer be used, even if they have been dried be-
fore use.
 Replace wet filters with new, dry filters (described
under point "Care and maintenance").
16
cleaning
Turning on the Appliance
WARNING
Health hazard due to fine dust. Check that the rotation
direction is correct before switching on the device. The
red indicator lamp lights up if there is a rotary field fault.
In this case, swap the pins on the device's plug (de-
scribed in chapter "Troubleshooting").
 Insert the appliance plug into the mains socket.
 Turn the On/Off switch to "1".
 Press "Switch-on appliance" button.
(only IVS 100/55 M and IVS 100/75 M)
 Perform the suction process.
 If necessary, clean or replace the filter (described
in chapter "Care and maintenance").
After each operation
Replace the disposal bag
See also "Emptying the vacuum cleaner waste contain-
er" in chapter "Shutting down".
 Lock parking brakes.
 Pull the locks of the placement mechanics up.
 Pull the push handle upward. The container is un-
locked and lowered.
 Pull the container out by the handle.
 Replace the dust bag (see chapter "Disposal sys-
tem").
 Reinsert the container and lock it with the push
handle.
 On completion of wet vacuum cleaning: Dry the fil-
ter. Clean the container with a moist cloth and dry
it off.
Cleaning the device
 Vacuum and wipe the appliance inside and outside
with a damp cloth.
A pressure gauge showing the vacuum inside the de-
vice is located on the front of the device. If the vacuum
is greater than the value given in the table, then the de-
vice must be switched off and the filter cleaned.
IVS 100/40
IVS 100/55
IVS 100/75
 Press the "Switch off appliance" switch.
 Move the filter cleaning lever back and forth several
times, but 5 times at least.
If this cleaning does not bring about any improvement,
then remove the filter and wash it or replace it (see
chapter "Replacing the filter").
Green indicator lamp
Lights up when the suction turbine is running
Blink codes for training the remote control (see ra-
dio remote control)
Lights if there is a rotary field fault.
Note: Appliance is not running.
Exchange the poles at the appliance plug.
– 5
EN
Suction process
Cleaning the filter
DN40
DN50
10 kPa
7.5 kPa
20 kPa
18.0 kPa
24 kPa
21 kPa
Indicator lamps
Red indicator lamp
DN70
--
10 kPa
12 kPa

Publicidad