6.2 LCD Menus
NOTE: For additional information about each menu, also refer to
Table 1, Quick Reference Chart (QRC), located after Section 9.0
of this manual.
A. Normal Operation "OK" Screen
Screen
22
(See Screen 2.) This indicates that the CB has booted
successfully ("OK"). Enter into the menus by pressing the Menu
button. See QRC step 1.
NOTE: If the pump is not equipped with the optional pressure
tranducer, the pressure reading will not be displayed.
B. "Units" Menu
(Models equipped with optional pressure transducer only)
Screen
33
SET
(See Screen 3.) This screen allows the operator to set the unit of
pressure-measurement by pressing the Down (Up) Arrow
buttons. PSI, BAR, Mpa are the options with PSI being the
default. Save setting and step forward by pressing the Menu
button. See QRC step 2.
The hidden menus for Dwell On/Off and Calibration are also
selected via the UNITS menu. See Section 6.5 for additional
instructions.
NOTE: The UNITS menu is available ONLY on models equipped
with the optional pressure transducer.
C. "Motor" Menu
Screen
44
MOTOR
4.8
HOURS CYCLES
(See Screen 4.) This screen allows the operator to read the
number of hours (On/Off cycles) the motor has been operated.
Toggle between hours and cycles by pushing either the Down
or Up Arrow button. Step forward by pressing the Menu button.
See QRC step 3.
OK
0
PSI
UNITS
PSI MPa
BAR
D. "Low Volt" Menu
Screen
56
LOW VOLT
HOURS CYCLES
(See Screen 5.) This screen allows the operator to read the
number of hours the pump has been operated in low-voltage
condition. Step forward by pressing the Menu button. See QRC
step 4.
E. "Advance" Menu
Screen
66
ADVANCE
188
HOURS CYCLES
(See Screen 6.) This screen allows the operator to read the number
of hours (On/Off cycles) the Advance solenoid has been operated.
Toggle between hours and cycles by pushing either the Down or Up
Arrow buttons. Step forward by pressing the Menu button. See
QRC step 5.
F. "Retract" Menu
Screen
77
RETRACT
334
HOURS CYCLES
(See Screen 7.) This screen allows the operator to read the
number of hours (On/Off cycles) the Retract solenoid has been
operated. Toggle between hours and cycles by pushing either
the Down or Up Arrow button. Step forward by pressing the
Menu button. See QRC step 6.
_________________________________________________________
General note for all hour and cycle displays:
HOURS DISPLAYED
- up to 9999.9 the display will show decimal hours
- between 10,000 - 99,999 whole hours will be displayed (decimal "." is not
displayed).
- over 99,999 hours the meter starts over at 0.0 reading decimal hours
CYCLES
DISPLAYED
- over 99,999 cycles the meter starts over at 0
_________________________________________________________