G. "Local" Menu
Screen
88
SET
OFF
(See Screen 8.) This screen allows the operator to toggle the Local
mode ON or OFF. With Local mode ON, the shroud buttons replace
the pendant buttons as the method to operate the pump (NOTE:
The word "Local" replaces "OK" on the "Normal Operations"
display and the pendant buttons become deactivated).
Local mode will provide operation of the pump if the pendant or
pendant cord is damaged. Toggle Local mode ON or OFF by
pressing the Down (Up) Arrow button. Save setting and step
forward by pressing the Menu button. See QRC step 7.
Local mode OFF is the default value. Local mode ON will revert
to Local mode OFF if power is disconnected.
H. "Language" Menu
Screen
99
ENGLISH
SET
(See Screen 9.) With a language shown on the text display the
operator can change the display language by pressing the Down
(Up) Arrow buttons. Save setting and step forward by pressing the
Menu button. See QRC step 8.
I. "Diagnose" Menu
Screen 10
DIAGNOSE
SET
00001
Pendant DOWN ARROW button
Pendant UP ARROW button
Pendant ON/OFF button
(See Screen 10.) This screen allows the operator to troubleshoot
several pendant problems by displaying if the microprocessor has
received a signal from the pendant button. No signal indicates the
problem is most likely with the pendant keypad or pendant cord.
Use Local mode to operate pump until problem can be corrected.
See QRC step 9.
LOCAL
PSI
(not used)
Fan
Screen 11
Press
(See Screen 11.) Diagnose screen with Pendant motor button
pushed.
Screen 12
Press
(See Screen 12.) Diagnose screen with Pendant Advance button pushed.
Screen 13
Press
(See Screen 13.) Diagnose screen with Pendant Retract button pushed.
8
DIAGNOSE
10001
PSI
DIAGNOSE
01001
PSI
DIAGNOSE
00101
PSI