Descargar Imprimir esta página

GYS SUPER PRO SMART EV CHARGE Manual De Instrucciones página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Operating manual
LIST OF AVAILABLE OPTIONS
Adaptor
Schuko
Swiss T13
GB / UK
CEE 16 Single-phase
CEE 32 Single-phase
CEE 16 Three-phase
CEE 32 Three-phase
TROUBLESHOOTING
Troubleshooting
+
+
+
12
Translation of the original
instructions
Disconnect the device from the power supply.
Limitation
10 A
8 A
13 A
16 A
32 A
16 A
32 A
Causes
Electrical fault.
Residual current detected in
electrical installation (>30mA).
Accessory fault.
Thermal protection.
Network
Single-phase
2.3 kW max
Single-phase
1.8 kW max
Single-phase
3 kW max
Single-phase
3.7 kW max
Single-phase
7.4 kW max
Three-phase
11 kW max
Three-phase
22 kW max
- Check your electrical installation and follow
the relevant electrical recommendations for
this type of product.
This error will only disappear after the
electrical installation has been brought into
conformity.
- The attachment connected to the device is
not a GYS accessory.
- Defect in the accessory. Contact your
dealer / service agent.
- Ambient temperature too high, ventilate the
room and let the charger cool down.
The load will automatically restart as soon
as the temperature is lower.
SUPER PRO SMART EV CHARGE