c. Remove the air filter.
d. Clean the air filter using a suction device or wash it with water and then dry it in a cool place.
e. Remove the refreshing filter (if supplied) from the air filter as shown in figure "38".
Do not touch this Electrostatic Filter within 10 minutes after opening the inlet grille,
it may cause an electric shock.
f. Clean the Electrostatic Filter with mild detergent or water and dry in the sunlight for two hours.
g. Insert the electrostatic filter again (if supplied) + the active charcoal filter (if supplied).
h. Insert the upper part of the air filter into the unit, paying attention that the left and right edges are correctly
aligned and then re-position the filter in the relevant seat (figure 39).
i. Close the panel well, taking it back to its original position.
10 - TROUBLESHOOTING
10.1 - SAFETY PRECAUTIONS
If one of the following conditions occurs, switch off and promptly disconnect the appliance.
• The power cord is damaged or heats up in an abnormal manner.
• You smell a burning odour.
• The unit emits loud or abnormal sounds.
• A power fuse blows or the circuit breaker frequently trips.
• Water or other objects fall inside the appliance.
IN THE PRESENCE OF THESE CONDITIONS, DO NOT TRY TO SOLVE THE ANOMALY BY YOUR-
SELF. PROMPTLY CONTACT A RETAILER OR AN AUTHORIZED ASSISTANCE CENTRE!
10.2 -COMMON ISSUES
The following problems are not a malfunction and in most situations will not require repairs.
Malfunctioning
The unit will not start.
The unit starts and stops
frequently
EN - 44
Cause
Current failure
The unit is disconnected from the
current.
A fuse has blown.
The remote control batteries may be
discharged.
The compressor 3 minute protection
has activated.
There's too much or too little refrigerant
in the system.
There is air, incompressible gas or
foreign material in the refrigeration
system.
System circuit is blocked.
The compressor is broken.
The voltage is too high or too low.
What must be done?
Wait for the current to be restored.
Check that the plug is inserted in the
wall socket.
Replace the fuse.
Replace the batteries.
Wait.
Check for possible leakage, contact
the assistance service if that occurs.
Contact the assistance service.
Contact the assistance service.
Contact the assistance service.
Install a manostat to regulate the volt-
age; contact the assistance service.