2
Informazioni sulla sicurezza
Informazioni sulla sicurezza per l'installazione secondo la normativa UL o UR
2.4
Informazioni sulla sicurezza per l'installazione secondo la normativa U
Warnings!
ƒ
ƒ
ƒ
ƒ
ƒ
Tipo
E94APNE0104
E94APNE0364
116
All manuals and user guides at all-guides.com
Maximum surrounding air temperature: 55 °C.
Branch circuit protection:
Suitable for use on a circuit capable of delivering not more than 5000 rms
symetrical amperes, 500 V max., when protected by H, K5 or CC fuses.
Voltage of the fuses must at least be suitable with the input voltage of the
drive.
Control card protection:
External fuse for 24 Vdc supply voltage of control terminal X11. Rated 4 A
DC fuse UL248-14.
Use 60/75 °C copper wire only, except for control circuits.
Branch circuit protection
Fusibile [A]
15
40
o U
L
R
EDK94PNE36 DE/EN/FR/ES/IT 2.0