5
Wiring the installation backplane
Wiring
Design of the cables
5.3.2
Design of the cables
The cables used must comply with the approvals required for the location (e.g. UL).
ƒ
It is imperative to comply with the regulations concerning minimum cross-sections
ƒ
of PE conductors. The cross-section of the PE conductor must be at least as large as
the cross-section of the power connections.
The effectiveness of a shielded cable is reached by:
ƒ
– Providing a good shield connection through large-surface shield contact.
– Using only braided shields with low shield resistance made of tin-plated or
nickel-plated copper braid.
– Using braided shields with an overlap rate > 70 % and an overlap angle of 90 °.
– Keeping unshielded cable ends as short as possible.
Use system cables or shielded cables for these connections:
External brake resistor ( Mounting Instructions of the brake resistor)
ƒ
The following connections need not be shielded:
Mains
ƒ
5.3.3
Terminal assignment
Tip!
Complete the wiring of the installation backplane before plugging in the
standard device. The upper terminals of the installation backplane cannot be
connected with a plugged-in standard device.
48
All manuals and user guides at all-guides.com
EDK94PNE36 DE/EN/FR/ES/IT 2.0