24 V supply
Terminal X11
SSP9400X11
Terminal data
Flexible
With wire end
ferrule
Digital inputs and digital outputs
Terminal X12
SSP9400X12
Terminal data
Flexible
With wire end
ferrule
EDK94PNE36 DE/EN/FR/ES/IT 2.0
All manuals and user guides at all-guides.com
Labelling
Description
GE
GND external supply
24E
24 V external supply through safely separated power supply unit
(SELV/PELV)
Conductor cross-section
2
[mm
]
0.2 ... 2.5
Labelling
Description
GOI
GND digital out / in
DI1
Brake chopper input - for discharging after mains disconnection only
DO1
Mains OK
DO2
Brake chopper active
DO3
Short circuit in brake chopper
DO4
Heatsink overtemperature
Wire breakage in the NTC
Conductor cross-section
2
[mm
]
0.2 ... 2.5
Wiring the standard device
Tightening torque
[AWG]
[Nm]
24 ... 12
Tightening torque
[AWG]
[Nm]
24 ... 12
7
[lb-in]
Spring terminal
[lb-in]
Spring terminal
53