Status display / Error codes
The symbols in the table below show the meter's operational status. The status
messages only appear in the main display (energy). The temporary display of
the warning triangle can be caused by special operating states and does not
always mean that the device is malfunctioning. However, should the symbol be
displayed over a longer period of time, you should contact the service company!
Symbol
external voltage (only by M-Bus)
Flow rate
existent
Attention!
Emergency operation
Complete symbol permanently displayed:
The meter is connected to LoRa server (join accept)
Wave symbol flashes, vertical bar permanently displayed:
Connection attempt with LoRa server (join request)
Only vertical bar permanently displayed:
Connection attempt with LoRa server failed (join failed)
Note: When the optical interface is activated, the wave symbol shows its
status (see above)
Code
Error type resp. possible reason
1
Temperature below of measuring range
2
Temperature above of measuring range
3
Short circuit return sensor
4
Interruption return sensor
5
Short circuit supply sensor
6
Interruption supply sensor
7
Battery voltage
8
Hardware error
9
Hardware error
10
Error in the measuring system
20
No water in the measuring tube
30
Reverse water flow detected
40
Air inside the medium
50
Measured value outside overload range
100
Hardware error
800
Wireless interface
1000
Status end of the battery
2000
Status initial verification expired
(*)
The validity period for the calibration depends on the country, please observe the
relevant national regulations.
(**) only by zelsius
Error codes show faults detected by zelsius® C5. If more than one error appears, the sum of
the error codes is displayed: For example, Error 1005 = error 1000 and error 5.
28
Status
Symbol flashing: Data transmission
Symbol constantly displayed: optical inter-
face active
C5-IUF
®
Action
-
-
Check system /device
for errors
-
-
Exchange device
Action
Check sensors
Check sensors
Check sensors
Check sensors
Check sensors
Check sensors
Exchange device
Exchange device
Exchange device
Exchange device (**)
Check operating pressure (**)
Check installation position (**)
Vent system (**)
Check dimensioning (**)
Exchange device
Exchange device
Exchange device respectively
battery(*)
Exchange device