2. To protect the pipe and cables from cutting and rubbing on the
wall, you must install a protective ring and seal it with mastic.
Note: Normally the hole in the wall is 60-80mm in diameter. Avoid
making the hole above pre-installed cables and on excessively hard
walls.
Gas line direction
The pipe can be installed in 3
different
directions,
as
shown
in
the
drawings.
When the pipe is installed in
position 1 or 3, make a cut
with the cutter.
Install
the
pipe
in
the
direction of the hole in the
wall.
Do not bend the pipe too
much and try to extend or
stretch it as shown in the
pictures.
Install the connection pipe
1.Screw the hex nut on the left side of the joint until it is secure.
57