14-ANTI-F
The Anti-F function works when the unit is turned off with the
remote control in COOL, DRY or AUTO mode. It will operate in HEAT
mode (FAN mode for cool only units), with the internal fan running
at low speed for 3 minutes before stopping, to remove moisture in
the evaporator to prevent bad odors due to mold.
This function is not programmed at the factory. You must program
it or cancel it at any time as follows: with the unit and the control off,
point the remote control at the unit and press the ANTI-F button
once, then a beep will sound 5 times indicating that the function is
programmed. Once set, this function will remain active except when
the unit is turned off or cancelled.
*To cancel the ANTI-F function
1- turn off the unit
2- With both the unit and the remote control turned off, point the
remote control at the unit and press the ANTI-F button once, a beep
will sound 3 times after 5 times, indicating that this function has
been cancelled.
Note:
*With ANTI-F activated, it is advisable not to turn the unit back on
until it is completely off.
*The ANTI-F function will be invalidated when a sleep timer is set.
15-ELE.H/ECO
This button has two functions:
a. ELE.H
If you press the button during the HEAT mode, the electric heating
will be switched off/on.
b.ECO