Device is not building up pressure
Check nozzle for correct size (see tech-
nical specifications).
Appliance ventilation:
Unscrew the nozzle. Switch on the appli-
ance and let it run until the water exiting
from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Clean/ replace nozzle.
Clean filter at the water connection.
Unscrew the filter casing, remove the fil-
ter, clean it and replace it.
Check water inlet quantity (see technical
specifications).
Check all supply lines to the HP pump for
leaks or blockages.
High pressure side is leaky
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.
High pressure pump is vibrating
Check all supply lines to the HP pump for
leaks or blockages.
Appliance ventilation:
Unscrew the nozzle. Switch on the appli-
ance and let it run until the water exiting
from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Warranty
The warranty terms published by our com-
petent sales company are applicable in each
country. We will repair potential failures of
the appliance within the warranty period free
of charge, provided that such failure is
caused by faulty material or defects in fabri-
cation.
The warranty comes only into effect if your
vender fills out the supplied reply card com-
pletely at purchase, stamps and signs and
you send it to the local distribution company
of your country.
In the event of a warranty claim please con-
tact your dealer or the nearest authorized
Customer Service centre. Please submit the
appliance, including all accessories, and the
proof of purchase.
General notes
Accessories and Spare Parts
– Only use accessories and spare parts
which have been approved by the manu-
facturer. The exclusive use of original ac-
cessories and original spare parts
ensures that the appliance can be oper-
ated safely and troublefree.
– At the end of the operating instructions
you will find a selected list of spare parts
that are often required.
– For additional information about spare
parts, please go to the Service section at
www.kaercher.com.
Guidelines for liquid rays
The accident prevention regulation (BGR
500) "Work with liquid rays" is valid. High
pressure spraying units must be checked
every 12 months in accordance with these
guidelines by an expert and the result of this
check must be written down.