Squeegee Blade Adjustment; Battery Maintenance - Tennant T3 Manual De Operador Y Lista De Repuestos

Fregadora--secadora
Ocultar thumbs Ver también para T3:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
4. To replace the front blade, remove the rear band
and fully loosen the four squeegee assembly
knobs, do not remove the knobs. Lift and tilt the
retainer plate to access the front blade
(Figure 53). Rotate the front blade to a new wiping
edge and return the retainer plate. Make sure the
retainer plate tabs engage the blade slots.
Reinstall the band then retighten the knobs.
Retainer Plate
FIG. 53

SQUEEGEE BLADE ADJUSTMENT

The adjustment of the squeegee blades are factory set
and require no further adjustment. Squeegee
adjustment is only necessary if it comes out of
adjustment.
For optimum squeegee blade performance, the
squeegee assembly casters must be adjusted to a
specified height as described below.
1. To check the squeegee assembly for proper
adjustment, remove the squeegee assembly from
the machine and place it on a level surface.
Measure the distance between the caster and the
surface. It should measure approximately 3 mm
(1/16") (Figure 54).
2. To adjust the caster height, loosen the top nut and
remove the plastic bearing cover to access the
adjustment nut. Turn the adjustment nut until
properly adjusted (Figure 54). After adjusting,
tighten the top nut and replace the plastic bearing
cover. Repeat step for the other caster.
FIG. 54
20
3 mm
1/16"
Home
Find... Go To..
3. During machine operation, with the casters
properly adjusted, the squeegee blades should
deflect as shown (Figure 55).
FIG. 55

BATTERY MAINTENANCE

WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
1. Check the specific gravity using a hydrometer to
determine the charge level and the condition of the
batteries (Figure 56). If one or more of the battery
cells read lower than the other battery cells (0.050
or more), the cell is damaged, shorted, or is about
to fail. Check the hydrometer readings against the
following chart to determine the remaining battery
charge level.
NOTE: Do not take readings immediately after adding
distilled water. If the water and acid are not thoroughly
mixed, the readings may not be accurate.
FIG. 56
Tennant T3 (08- -05)

Publicidad

Tabla de contenido
loading

Tabla de contenido