Directions for use
If the installation of the thermostove provides interaction
with another existing system complete with a heater (gas
thermostove, gas thermostove, oil thermostove, etc..)
consult qualified personnel who can then answer the
compliance of the system, as envisaged by the law in
force.
Flushing the system
In accordance with the UNI-CTI 8065 is strongly
recommended to wash the entire system before
connecting it in order to get rid of residues and
deposits.
After flushing the system to protect it against corrosion
and deposits, it is recommended the use of inhibitors.
Upstream from the stove, always install shutters so as
to disconnect it from the plumbing system should it be
necessary to move it, or when it requires routine and/or
special maintenance. Connect the stove using hoses so
that the stove is not too strictly connected to the system,
and to allow slight movement.
These are as helpful as the supply and return piping
system if the heating system is on a higher floor than the
stove.
The exhaust pipe pressure is connected temporarily to a
carafe or a funnel to avoid, in case of overpressure, that
the water gush bathrooms and the structure and the floor.
Replenishment of the System
The replenishment has to be slowly carried out in order to
let the air bubbles flow out through the right oulets that
are placed on the heating system.
In heating systems with a closed circuit the loading cold
pressure of the system and the inflation pressure of the
expanding vase must correspond.
54
• in heating systems with open vase, the direct contact
between the circulating liquid and the air is allowed.
During the heating-season the user must regularly check
the circulating water level in the expansion vase.
The content of water in the system of recirculation must
be stable hold.
Experiences show that the user must regularly check the
water level every 14 days in order to maintain a stable
water content.
The replenishment process must be carried out in case
of necessity of more water when the thermostove has
cooled down.
These preventive measures aim to prevent the insurgence
of thermic stress of the steel body of the thermostove.
• in systems with open vase, the pressure of water in
thermostove, when the system is cold, mustn't be lower
than 0,3 bar;
• the water used to fill up the heating system must be
decontaminate and without air.
When all the hydraulic connections are done, proceed to
test the pressure of the seals, through the filling of the
heating stove.
VENTING
The loading valve is required and must be provided in
SAFETY
the hydraulic system.
VALVE
This operation must be carried out with caution following
these steps:
• open the vent's valve of the radiator ,of the thermostove
and the system;
• Gradually open the filling tap of the system checking
that the automatic vent's valves, placed on the system,
are regularly working;
• Close the vent's valves of the radiators as soon as the
air flows out;
• check through the pressure gauge placed in the system
You must not mix water of the heating
system with antifreeze or anticorrosion
substances in wrong concentrations.
This could ruin the seals and provoke
the insurgence of noises while operating.
The producer refuses any responsibility for
damages towards persons, animals or things if
this warning will not be respected.
STOPPER BLOCKED
LOOSE STOPPER
ONE TURN

Publicidad