Cleaning exchanger - stove off
Fouling act as insulation and the thicker they are, the
lower the heat that is transmitted to the water and to the
structure generally. Therefore very important to perform
the cleaning of the tube bundle, said exchanger also, to
prevent the fouling of the same and prevent clogging and
jamming of the cleaning device. Pull and push quickly for
5-6 times the lever so that the springs can remove the
soot deposited on the pipes.
Check every 2/3 days
Cleaning the ash collection compartment
Clean and empty the ash tray being careful with hot ash.
The ash must be completely cold for a vacuum cleaner to
be used to remove it. Only if the ash is completely cold,
you can also use a canister vacuum cleaner suitable for
picking up particles of a certain size.
Cleaning ash and combustion chamber including the
spark plug lead.
Cleaning of stainless steel and satin-finish surfaces
Normally these surfaces do not need to be treated, but
if they do, avoid cleaning them with abrasive materials.
For surfaces in stainless and satin brushed steel we
recommend cleaning with a paper towel or a clean dry
cloth moistened with a detergent based on non-ionic
surfactants (<5%) A spray glass cleaner may be used.
Avoid contact with skin cleanser
and eyes. In case this happens,
sprinkle with plenty of water and
contact the nearest medial center.
80
Cleaning of painted pats
Do not clean the painted parts with wet rags when the
unit is in operation or hot to prevent thermal shock to the
paint which may cause it to detach. Do not use abrasive or
aggressive products or materials. Clean with damp cotton
or paper towels. The silicon paints used by manufacturer
possess technical characteristics that make them resistent
to very high temperatures. There is however a physical limit
(380° C - 400° C) beyond which the paint begins to fade or
(over 450°) to vitrify; it may then flake and detach from the
steel surface. If this happens, it means that temperatures
have been reached that are far above those at which the
unit should operate properly.
Do not use abrasive materials or
harsh. Clean with damp cotton or
paper towels.
Check every 7 days
Lower ash drawer cleaning
Clean bottom ash from the fallen debris during operation.
You can access the ash pan by loosening the two wing
nuts that hold the drawer inspection. Remove the tray,
empty and clean the wall and only the corners with a
suction device or with dedicated tooling. Then mount the
drawer and tighten the two knobs being careful to restore
the tightness, very important during operation.
Cleaning the interior baffle / smoke fan compartment.
Inside the compartment where there is the ash tray, there is
a second cover, fixed by the cockerels, which gives access to
the compartment at the base of the duct dedicated to the
flue and the wall of the fume extractor fan. Use a suction
device for thorough cleaning of the cabinet. Check the
integrity of the seal in ceramic fiber.