Pellet build up in
grate, door glass gets
dirty and flame is
weak
The smoke extraction
motor does not work
The air fan convention
never stops
In the automatic
position the
thermostove always
runs at full power
The thermostove
starts up "alone"
The power does not
change even if you
manually adjust
1. Insufficient combustion air
2. Pellets damp or unsuitable
3. Smoke extractor motor broken
4. Bad adjustment. Wrong ratio
between air and pellet
1. No electrical supply to
the thermostove
2. The motor is broken
3. Defective electronic board
4. Control panel broken
1. Temperature sensor
temperature control defective
or broken
2. Fan failure
1.
Room
thermostat
maximum
2. Temperature sensor defective
3. Control panel defective or
broken
1. Incorrect programming of the
cronothermostat
1. The board is set to automatic
correction of power in proportion
to the temperature
1. Check that the room air intake is present and free.
Check that the pipe Ø 5 cm for air inlet is not
obstructed.
Clean the grate and check that all the airways are clear.
Carry out a general cleaning of the combustion
chamber and the smoke duct.
Check the state of the door gaskets
2. Change the type of pellet
3. Check the motor and replace if necessary
4. Contact your Authorized Assistance Center
1. Check the supplay voltage and the protection fuse
2. Check the motor and capacitor and replace
if necessary
3. Replace electronic board
4. Replace the control panel
1. Check operation of the sensor and replace
if necessary
2. Check operation of the motor and replace
if necessary
set
to
1. Reset the thermostat temperature
2. Check the operation of the sensor and replace
if necessary
3. Check the panel and replace if necessary
1. Check the settings of the cronothermostat
1. Contact your Authorized Assistance Center