Descargar Imprimir esta página

Kärcher BD 70/75 W Classic Bp Pack 80 Ah Li Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

BD 70/75 160 Ah:
Battery
1
Battery pole
2
Circular connector
3
Spacer 150x150x65
4
Spacer 155x300x60
5
5. Insert the spacers and additional weights as indicated.
ATTENTION
Risk of damage
If the polarity (plus and minus terminal) is reversed, the
control electronics will be damaged.
Connect the red cable to the plus terminal and the black
cable to the minus terminal.
Observe the illustrations shown above when connecting
the cables.
6. Clamp the connecting cables onto the (+) and (-) battery
terminals.
7. For the devices with two batteries, attach the connecting
cable between the two batteries.
8. Plug the circular connectors into the batteries.
9. Connect the device-side battery connector to the bat-
tery-side battery connector.
10.Pivot the waste water tank downwards.
Note
Charge the batteries before starting up the device (see
section "Charging the batteries").
Removing the batteries
CAUTION
Removing and installing the batteries
Unstable machine position
Ensure that the machine is positioned stably when remov-
ing and installing the batteries.
1. Turn the key-operated switch to "0" and remove the key.
2. Disconnect the battery plug.
3. Drain the waste water.
4. Pivot the waste water tank upwards.
5. Unplug all circular connections.
6. Disconnect the device-end cable from the negative ter-
minal of the battery.
7. Disconnect the remaining cables from the batteries.
8. If necessary, remove the spacers.
9. Remove the batteries.
10.Dispose of the used batteries in accordance with statu-
tory provisions.
DANGER
Inappropriate use of the charger
Electric shock
Adhere to the mains voltage and fuse values specified on
the device type plate.
Only use the charger in dry rooms with sufficient ventila-
tion.
ATTENTION
Using an unsuitable charger
Risk of damage
Do not connect the charger to the device-side battery con-
nector.
Use only a charger suitable for the type of battery installed.
Read the operating instructions of the charger manufactur-
er and observe the safety instructions in particular.
The device cannot be used during the charging process.
Note
The device has deep discharge protection, i.e. the brush
motor and turbine are switched off automatically when the
permitted minimum capacity level is reached.
1. Drive the device directly to the charger and do not drive
on slopes.
2. Pull out the device-side battery connector.
1
Battery plug, device side
1
Battery plug, battery side
2
ATTENTION
Risk of damage
Do not connect the charger to the device-side battery con-
nector.
Note
Please read the operating instructions of the charger man-
ufacturer, especially the chapters on safety instructions!
3. Connect the battery-side battery connector to the charger.
4. Plug the mains plug of the charger into the socket.
5. Carry out the charging process in accordance with the
operating instructions for the charger.
The charging time depends on the battery condition and
the charger. When the battery is empty, the charging
time is approximately:
Charger
6.654-483.0
6.654-484.0
English
Initial startup
Charging the battery
Battery capacity Charging time
approx.
80 Ah
7 hours
80 Ah
2 hours
160 Ah
4 hours
1