1.
Turn off any connected electric devices and stop the engine.
2.
Reduce the total wattage of connected electric devices within the
rated output.
3
Check for blockages in the cooling air inlet and around the control
.
unit. lf any blockages are found remove them.
4.
After checking, restart the engine.
NOTE
The Overload Alarm may come on for a few seconds when first using electrical devices that
require a large starting current, such as a compressor, pump, or refrigerator. This is normal
behavior it is not a malfunction.
Low Oil Alarm (Red)
When the engine oil falls below the required level the Low Oil Alarm will
come on and the engine will stop automatically. The engine will not restart
until oil is added to the unit to bring it up to the appropriate level.
NOTE
When starting the unit, if the Low Oil Alarm light flickers and the engine will not start, you
will need to add engine oil before attempting to restart the engine.
NOTE
Generator should only be operated on a level surface. DO NOT operate the generator on
loose ground or obvious inclines. The low oil shutdown feature may be prematurely
activated in these cases causing the engine to not start.
Engine Switch
The Engine Switch controls the ignition switch. The switch must be in the
"I" position to start the generator. Switching to the "O" position stops the
engine and will not allow the engine to be restarted.
INVERTER GENERATOR – P2000i
15