INVERTER GENERATOR – P2000i
N Check the following
Fuel line clogging
Air cleaner
element clogging.
7.2
Fuel Filter Maintenance
Use this section to troubleshoot common errors.
Engine won't start
Fuel systems: No fuel supplied to combustion chamber
• No fuel in tank supply fuel.
• Fuel in tank
to "I".
• Clogged fuel line...clean fuel line.
• Clogged carburetor...clean carburetor.
Engine oil system insufficient
• Oil level is low...add engine oil.
Electrical systems
• Engine switch to "I" and pull the recoil starter. Poor spark
• Spark plug dirty with carbon or wet... Remove carbon or wipe spark
plug dry.
• Faulty ignition system...Consult a service center.
Generator won't produce power
• Safely device (DC protector) to "O" ...press the DC protector to "I"
Clogged
O
OK
P
Fuel tank cap air vent knob to "ON" and fuel cock knob
40
K Check the spark plug.
Type: BPR6HS
Gap: 0.6-0.7 mm (0.024-
0.028 in)
L Incorrect
M OK
Replace
or
Clean the spark
adjust Gap.
plug.
Q Clean or Replace; Consult a
dealer.
R Consult a dealer.