TROUBLESHOOTING AND SPECIFICATIONS
7.1
Troubleshooting Diagram
A ENGINE DOES NOT START
B Turn the engine switch to "ON", then pull the
recoil starter and c heck if the oil warning light
flickers
C Does not flicker
H Pull the recoil starter and check the spark plug
for spark strength. (See "WARNING")
WARNING
To Prevent FIRE HAZARDS be sure
fuel is not present in the spark plug
area.
To prevent FIRE HAZARDS be sure to
place the spark plug as far way as
possible from ste spark plug hole and
carburetor area.
To prevent ELECTRIC SHOCK do not
hold spark plug lead with hand while
testing.
I OK
SEE N to the next page
D Flicker
J Dose not spark
INVERTER GENERATOR – P2000i
E Check engine oil level
F OK
Consult a dealer
SEE K to the next page
39
G Level low
Add engine oil