INVERTER GENERATOR – P2000i
4.5
Battery Charging
Start the engine first and allow it to reach idle before connecting the generator
to the battery. Battery Charging is performed using the 12V DC outlet only.
1. Be sure the Throttle switch is turned "O" while charging batteries.
2. Be sure to connect the red battery charger lead to the positive (+) battery
terminal, and connect the black lead to the negative (-) battery terminal.
DO NOT reverse these positions.
3. Connect the battery charger leads to the battery terminals securely so that
they are not disconnected due do engine vibration or other disturbances.
4. Charge the battery by following the instructions in the owner's manual for
the battery.
5. The DC Circuit Breaker will turn "O" automatically if the current exceeds
rated output.
6. To restart charging the battery, turn the DC protector on by pressing its
button to "I"
7. Refer to the owner's manual for the battery to determine charging times.
NOTE
Never start or stop the generator with electrical devices plugged in or turned on.
28