COMMISSIONING
8
Minimum distance in mm (y) between the set sensing
range and background (white, 90%)
y
140
WTS26P-xxxxx1xx
120
1
100
6%/90%
80
60
40
20
0
0
400
800
Figure 4: Characteristic line 1
Sensing range on black, 6% remission
1
Sensing range on gray, 18% remission
2
Sensing range on white, 90% remission
3
1
40
150
700
2
25
150
3
10
150
0
150
300
500
(5.91)
(11.81)
(19.69)
(27.56)
Distance in mm (inch)
A
Adjustment range
A = Detection distance (depending on object remission)
Figure 5: Bar graph 1
Sensing range setting
WTS26x-xxxxxx2xAxx with press-turn element
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: sensing range increased.
Counterclockwise rotation: sensing range reduced.
The sensing range can also be adjusted using just the potentiometer. We recommend
placing the object within the sensing range,
been adjusted, the object is removed from the path of the beam, which causes the
background to be suppressed and the switching output to change
18%/90%
2
Example:
3
Sensing range on black, 6%,
90%/90%
x = 500 mm, y = 25 mm
x
1,600
1,200
Distance in mm
900
1,000
700
1,000
(39.37)
BluePilot:
Sensing range
indicator (blue LED)
Teach-Turn
adjustment
see figure
white background (90%)
x
y
6. Once the sensing range has
(table
1,
table
8020355 | SICK
Subject to change without notice
2).