Descargar Imprimir esta página

Whirlpool 86999 Serie Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
INSTALLATION CLASS 3
TECHNICAL INFORMATION FOR THE INSTALLER
Use protective gloves for handling, preparing, and installing the product.
This product can be embedded in a worktop 20 ÷ 60 mm thick.
If there is no oven beneath the hob, insert a separator panel with a surface at least equal to the work surface's opening This panel must be positioned
at a maximum distance of 150 mm below the upper surface of the work surface but, in no case less than 20 mm from the bottom of the hob. In case
you intend to install an oven beneath the hob, make sure that it is equipped with a cooling system.
DIMENSIONS AND DISTANCES TO BE MAINTAINED
20-60
mm
NOTE: If distance "A" between the kitchen cabinets is between 600 mm and 730 mm, height "B" must be at least 530 mm.
If distance "A" between the kitchen cabinets is greater than the width of the hob, height "B" must be at least 400 mm.
If a hood is installed above the hob, refer to the assembly instructions for the hood to see the necessary distance.
ASSEMBLY
After cleaning the perimeter surface, apply the supplied gasket to the hob as shown in the gure.
Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.
NOTE: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow
and fasten them by means of their screws in accordance with the thickness of the worktop (see the following gures).
20 mm
A
GAS CONNECTION
Connect elbow (A)* or (B)* supplied with to the hob inlet main pipe and interpose the washer (C) supplied, in compliance
with EN 549.
* Use elbow (A) for France and elbow (B) for all other destinations.
After connection to the gas supply, check for leaks with soapy water. Light up the burners and turn the knobs from max
position
to minimum position to check ame stability.
ELECTRICAL CONNECTION
L
Ground cable
(yellow / green)
N
min. 55 mm
min. 6,5 mm
max. 8
30 mm
20
Min. 750 mm
40 mm
30
EN
A
B
Min. 100 mm
60 mm
40
C
C
C
60
A
B

Publicidad

loading