2.3 General Calibration Operations for LDW System
2.3.1 Precondition for the Use of the PHOENIX ADAS MOBILE
Regard the following in order to use the PHOENIX ADAS MOBILE:
• Vehicle system is working properly.
• No trouble codes stored in ECU memories.
• Prepare
calibration reference pattern.
• A diagnostic tool supporting ADAS system calibrating is required (sold separately).
• Front & rear axle track is properly adjusted.
• To calibrate accurately, please make sure the following workstation requirements are met (See Chapter
2.4.1.1 ~ Chapter 2.4.1.3).
2.3.1.1 Workstation size
A. For front cameras
Distance A = the width of the cross member
Distance B = about 1m / 39.4inch (from the cross member to the wall)
Distance C = at least 0.5m / 19.7inch (from the edge of the cross member to other obstacles)
Distance D = varies from vehicle to vehicle, about 1.5m / 59inch is strongly recommended (from the
calibration panel to the vehicle)
Distance E = reserved for about 1m / 39.4inch (from the vehicle to other obstacles)
Distance F = at least 0.5m / 19.7inch (a lane for technician to walk through)