Descargar Imprimir esta página

Fulgor Milano FBCD 355 TNF EDBL Instrucciones De Instalacion Y Uso página 32

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
EN
An air intake should be
provided somwhere in the
cabinet run to allow free air
in. In this example a plinth
vent is shown underneath
the refrigerator.
A cutout should be made
in the plinth below the
fridge/freezer
finished neatly using the
air vent grille.
Alternatively a thin section
of
the
removed to allow air into
the
unit
600mm x 10mm)
The open channel at the rear is clearly shown. For the
correct operation of the appliance it is important that the
top of the housing unit is not blocked off. A channel depth
of 40-50mm is normal with most units.
A ventilation hole is required in the plinth of the unit;
this allows air to be drawn over the compressor & heat
exchange.
As a rule, the more air that can get in and out, the better and
more efficient the operation of the product.
12
and
this
plinth
can
be
(recommended
plan view of rear ventilation gap
The top of the cabinet needs to be
Refrigerator
vented into the room.
outline
Recommended size of vent opening:
50-0 it 30mm.
If the furniture does not allow free air
into the room then a plinth vent, or
other means of ventilation needs to
be provided to ensure a natural flow
of air.
Min. 30 mm
There should be space at the rear of
the cabinet to allow cool air to be
drawn over the condenser.
Recommended: 500 x 35mm

Publicidad

loading

Este manual también es adecuado para:

Fbcd 751 tnf edbl