2.3 Positioning of bottles
- Compressed gas cylinders are dangerous; consult the supplier
before handling them.
Protect them from:
- direct exposure to sun rays;
- flames;
- sudden changes in temperature;
- very low temperatures.
Compressed gas cylinders must be fixed to the walls or to
other supports, in order to prevent them from falling.
2.4 Installing the apparatus
- Comply with the local safety regulations for the installation
and carry out the maintenance service of the machine
according to the constructor's directions.
- Any maintenance operation must be performed by qualified
personnel only.
- The connection (series or parallel) of the generators is prohi-
bited.
- Before operating inside the generator, disconnect the power
supply.
- Carry out the routine maintenance on the equipment.
- Make sure that the supply mains and the earthing are suffi-
cient and adequate.
- The earth cable must be connected as near the area to be
welded as possible.
- Before welding, check the condition of the electric cables and
of the torch, and if they are damaged repair or change them.
- Neither get on the material to be welded, nor lean against it.
- The operator must not touch two torches or two electrode
holders at the same time.
- Protect the system against driving rain and the sun.
2.5 Connection
The SELCO mobile units are powered exclusively at low voltage.
You are nevertheless advised to observe the elementary precau-
tions illustrated in detail in the power source operating manual.
Before carrying out any work, replacement or
repair of parts, ensure that the power source is
disconnected from the power supply line.
2.6 Commissioning
2.6.1 WF114/WF115 XP Start-up
14
Fig.1 Details of the trolley
a)
Disconnect the power supply from the power source.
b)
Open the left-hand side cover.
c)
Connect the signal cable (1) to the appropriate connector.
d)
Connect the power cable (2) to the appropriate fastening.
e)
Tighten the cable clamps and close the left-hand side cover.
f)
Connect the gas pipe to the rear hose fitting.
g)
Open the trolley mobile bonnet, exerting pressure on the
two slide fastenings, and remove any accessory elements
provided in the compartment.
h)
Check that the roller groove coincides with the diameter of
the wire you wish to use.
i)
Unscrew the ring nut (G1) from the coil reel and insert the
coil.
Fit the reel metal pin into its housing, replace the ring nut
(G1) and adjust the friction screw (G2).
l)
Release the feed support of the gearmotor (M1), sliding the
end of the wire into the wire guide bush and, passing it over
the roller, into the torch fitting.
Lock the feed support (M1) in position, checking that the
wire has entered the roller groove.
m) Insert the torch, complete with sheath, into the central fit-
ting (C1), fully tightening the ring nut.
2.7 Accessory
COMPOSITION
WF114 driven roller upgrade kit
Wheel kit
WF115 XP 2-4 roller upgrade kit
CODE
07.01.504
73.10.047
07.01.502