Remark: Above table is just for reference only. In determining
the storage period, always suggesting the local sanitary-epi-
demiological regulations and HACCP.
Cleaning & maintenance
• ATTENTION! Always disconnect the appliance from the elec-
trical mains and cool down before storage, cleaning & main-
tenance.
• Do not use water jet or steam cleaner for cleaning and do not
push the appliance under the water as the parts will get wet
and electric shock might be resulted.
• If the appliance is not kept in a good state of cleanliness, this
can adversely affect the life 0of the appliance and result in a
dangerous situation.
• Food residues should be regularly cleaned and removed from
the appliance. If the appliance is not cleaned properly, it will
reduce its lifespan and may result in a dangerous condition
during use.
Cleaning
• Clean the cooled exterior surface with a cloth or sponge
slightly dampened with a mild soap solution.
• For reasons of hygiene, the appliance should be cleaned be-
fore and after use.
• Avoid water contacting the electrical components.
• Never use aggressive cleaning agents, abrasive sponges, or
cleaning agents containing chlorine. Do not use steel wool,
metallic utensils, or any sharp or pointed objects for cleaning.
Do not use petrol or solvents!
• Never immerse the appliance in water or other liquids.
Maintenance
• Check the operation of the appliance regularly to prevent se-
rious accidents.
• If you see that the appliance is not working properly or that
there is a problem, stop using it, switch it off and contact the
supplier.
• All maintenance, installation and repair work must be car-
ried out by specialised and authorised technicians, or recom-
mended by the manufacturer.
Transportation and Storage
• Before storage, always make sure that the appliance has
been disconnected from the power supply and completely
cooled down.
• Store the appliance in a cool, clean and dry place.
• Never place heavy objects on the appliance as this could
damage it.
• Do not move the appliance while it is under operation. Dis-
connect the appliance from power supply when moving and
hold it at the bottom.
Troubleshooting
If the appliance does not function properly, please check the
below table for the solution. If you are still unable to solve the
problem, please contact the supplier/service provider.
Problems
Possible solution
Appliance will
• Ensure that the machine is properly plugged
not turn on
into a grounded outlet.
• Check the power cord for tears and frays. Do
not use machine if power cord is damaged.
• Make sure the Power button was properly
pressed. LED screen will be illuminated
when on.
Appliance does
• Vacuum/seal time may not be set high enough.
not pull
Set vacuum and seal times higher and vacuum
a complete
again.
vacuum with
• To vacuum and seal properly, the opening of
pouch
pouch must be within the vacuum chamber.
• If packaging from a roll pouch, make sure
first seal is complete and there are no gaps
in either seal.
• Vacuum packaging machine and vacuum
pouch need to be clean, dry and free of debris
for the vacuum process to be successful. Wipe
surface of seal bar and inside of pouch and
try again.
Vacuum pouch
• Sharp items can puncture small holes in
loses vacuum
pouches. To prevent this, cover sharp edges
after being
with paper towel and vacuum in a new pouch.
sealed
• Some fruits and vegetables can release gases
(out-gassing) if not properly blanched or
frozen before packaging. Open pouch. If you
think food spoilage has begun, discard food.
If food spoilage has not yet begun, consume
immediately. If in doubt, discard food.
Appliance is not
• Seal time may not be long enough. Increase
sealing pouch
seal time and try again.
properly
• Pouches will not seal if any moisture, food
particles or debris are present
in the seal area. Wipe the inside of the pouch
clean and try again.
• Pouch must be properly placed along the seal
bar. Make sure the entire pouch is over the
seal bar and there are no wrinkles in pouch
material.
Error code identification
Error
Possible cause
codes
E01
When the
machine vacuum
for some time,
the two pressure
switches do not
close.
E02
When the
machine enters
into Seal mode,
the micro-switch
does not close.
LP
The power is lost
suddenly during
the operation of
machine.
Possible solution
• Check if the vacuum lid is close;
• Check if the sealing gaskets are
assembled correctly;
• Check if the pump still works;
• Check if the pressure switches
are still good (check the con-
necting pipe, pressure switches,
10P data cable, etc.)
• Check if the vacuum lid is close;
• Check if the micro-switch is
correct (GAS1 connecting wire,
micro-switch, 10P data cable,
etc.)
• Press "STOP" button to
release the air, then the LP will
disappear.
• If it appears again, please check
the power supply system (like
power cord, power socket, power
board).
GB