PROCEDURE FOR CONNECTING THE UNIT
IMPORTANT:
• The unit must be installed in accordance with national wiring rules.
• All cables with the unit, including accessories, must be type H05 VV-F, with PVC insulation according to EN
6033-2-40.
• Remove power to all circuits before accessing live parts.
• Connect the ground before the electrical connections.
According to the rules of installation, the device disconnects the power supply must provide a contact aperture (4
mm) that allows complete disconnection in the conditions of overvoltage category III.
Connect the power supply L (line), N (neutral) and (ground) as shown on wiring diagram, respecting the polarity
marked on the bottom of the electrical boxes.
All units are fitted with a fuse (type 1A gF) to protect the machine (3 Fig-2).
Electrical boards: electrical panel is located on the outer
side of the unit (1 fig. 1). Remove the electrical cover by
removing / locking screws.
IMPORTANT:
• To power the unit, it is recommended to use cables with a minimum as shown in tab. 1
• To lock the cable connections made with suitable flexible coupling (2 fig 2).
• Remember to close the control panel using a special protective cover, using the / lives / the previously
removed / e .
Model
Power supply
section cable
40
ELETRICAL CONNECTIONS
1
Fig. 1
Type
N
L
Terra
Tipo
Inside there are the terminal blocks (1 fig 2) which make the
connections as per circuit diagrams shown in Diagrams section
depending on the type of accessory selected command
Tutti
230-1-50
1,5
1,5
1,5
H05W-F
Fig. 2
3
U.M
V-Ph-Hz
mm
2
mm
2
mm
2
\