Parameters
Submenu 1
Submenu 2
S Point
R Point
W Low
W High
S Delay
R Delay
Out 2
Setting 2
Setting of a digital output (for Out 2 only analog options)
AVENTICS™ PE7 | R412028763-BAL-001-AA | English
Value range / op-
Meaning
tions
Nominal pressure
• Switching point in
range of the product
hysteresis mode,
at which the out-
put changes the
switching state
when the pressure
rises
• Compulsory at
least 1 increment
above the reset-
ting point R Point.
Nominal pressure
• Resetting point in
range of the product
hysteresis mode,
at which the out-
put changes back
to the original
switching state
when the pressure
falls
• Compulsory at
least 1 increment
below the switch-
ing point S Point.
Nominal pressure
• Lower switching
range of the product
point in window
mode, at which
the output
changes the
switching state
• Compulsory at
least 1 increment
below the upper
switching point W
High
Nominal pressure
• Upper switching
range of the product
point in window
mode, at which
the output
changes the
switching state
• Compulsory at
least 1 increment
above the lower
switching point W
Low
Increments of
Switching delay of the
0 ... 600 s / 0.01 s
switching state from
0 to 1 (NO) or from 1
to 0 (NC)
Increments of
Switch-back delay of
0 ... 600 s / 0.01 s
the switching state
from 1 to 0 (NO) or
from 0 to 1 (NC)
PNP
Digital, p-switching
NPN
Digital, n-switching
Push-Pull
Digital, p-switching
and n-switching (anti-
valent)
0 ... 10 V
Analog, voltage signal
0 ... 10 V
1 ... 10 V
Analog, voltage signal
1 ... 10 V
4 ... 20 mA
Analog, current signal
4 ... 20 mA
20 ... 4 mA
Analog, current signal
4 ... 20 mA, inverted
10 ... 0 V
Analog, voltage signal
0 ... 10 V, inverted
10 ... 1 V
Analog, voltage signal
1 ... 10 V, inverted
Parameters
Submenu 1
Submenu 2
Range Lo
Range Hi
3.5 Display
3.5.1 "Display" menu item
In the Display menu item, parameters for the display are set.
Table 1: Settings in the "Display" menu item
Parameters
Value range / options
Out Color
OFF
only detail
OUT 1
OUT 1 invert
OUT 2
OUT 2 invert
SPLIT
SPLIT invert
Rotation
0°
180°
Brightness
Increments of 0 ... 125 % / 1 % • Display brightness
Update rate
50 ms
200 ms
600 ms
Off time
Increments of 0 ... 3600 s / 1 s Time until the screen is auto-
Lock
simple
safe
Value range / op-
Meaning
tions
0 ... 80 % of nominal
• Analog starting
pressure range
point, at which
the lower limit
point of the ana-
log signal is out-
put
• Compulsorily at
least 20 % below
Range Hi.
20 ... 100 % of nomi-
• Analog end point,
nal pressure range
at which the up-
per limit point of
the analog signal
is output
• Compulsorily at
least 20 % above
Range Lo.
Meaning
No color display of switching
states of Out 1 or Out 2
• Color bar at top (Out 1)
and bottom (Out 2)
• Only active in main
menu 3
The display lights up depend-
ing on Out 1
The display lights up depend-
ing on Out 1
The display lights up depend-
ing on Out 2
The display lights up depend-
ing on Out 2
• The left half of the display
lights up depending on
Out 1.
• The right half of the dis-
play lights up depending
on Out 2.
• The left half of the display
lights up depending on
Out 1.
• The right half of the dis-
play lights up depending
on Out 2.
• Standard orientation
• Rotate display by 180°
• Recommendation: max.
100 %
• > 100 %: LED lighting ser-
vice life reduced
Update rate = 50 ms
Update rate = 200 ms
Update rate = 600 ms
matically locked in main
menu 2 and 3 or until the
screen is switched off in main
menu 1
Unlocking the screen with a
swipe gesture
Unlocking the screen by
pressing for 3 s and swipe
gesture
8