Descargar Imprimir esta página

Nemox gelato 12KST Instrucciones Para El Uso página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

attention to the bottom of the bowl), on the
central sleeve of the bowl, on terminal part of
the shaft (where the ring (4) is screwed) and
on the extrusion bowl opening. Check that all
the surfaces or recessed and/or hidden
areas, especially which can coming in
contact with food, are fully covered by
disinfecting agent. Use an har bristle brush or
any other tool previously sanitized in order to
facilitate the operation. Leave the disinfecting
agent for the time required (no less than 5
minutes).
•Pull out the scrapers (18), (19) and (21)
(simply by pulling them), the interlocking
buffers (20) (by pushing them out from the
blade) and the bush (17) from the paddle.
•Separate the ORs gaskets from the bush
(17), and from the ring (4).
•By unscrewing the aprropriate screw (14)
remove the chute (11).
•By unscrewing the aprropriate screws (12)
remove the frame (8) with the grid and his
basket.
•Remove the grid (9) and, by unscrewing the
appropriate screws (13), remove the
extrusion flange (24) and pull out the small
grid (25). Separate the gasket (16) and the
other sealing gasket from the flange (24).
•Fill 2 separated baskets with sanitizing
solution and fully immerse in the first basket
for the time required by the disinfecting agent
(no less than 5 minutes) the paddle (5), the
inserts (18), (19) and (21), the interlocking
buffers (20), the gate (9), the ring (4), the
flange (24), the small grid (25) the spoon (23),
the lid (3), the lid cap (3a) and his rubber
small cap and all the ORs gaskets and the
screws (13), (14) and (12).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the body and
the recessed and/or hidden areas of the
paddle (5). Pay utmost attention in cleaning
the internal sleeve, the blades and the zone
around the interlocking buffers (20). Leave it
fully immersed in the second basket with the
solution prepared above for the time required
(no less than 5 minutes).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the body and
the recessed and/or hidden areas of the bush
(17). Pay utmost attention in cleaning the ORs
gaskets throats. Leave it fully immersed in the
English
second basket with the solution prepared
above for the time required (no less than 5
minutes).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the body and
the recessed and hidden areas of the retainer
(4). Pay utmost attention in cleaning the OR
throat and the thread. Leave it fully immersed
in the second basket with the solution
prepared above for the time required (no less
than 5 minutes).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the body and
the recessed and/or hidden areas of the
inserts (18), (19) and (21) especially the
zones where the metal blade of the paddle
gets stuck. Repeat the operation twice. Fully
immerse the goods each time into an unused
disinfecting agent solution. Leave them all
fully immersed in the second basket with the
solution prepared above for the time required
(no less than 5 minutes).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the chute
(11) and his recessed and/or hidden areas.
Leave it fully immersed in the second basket
with the solution prepared above for the time
required (no less than 5 minutes).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the frame (8),
the grid and the basket and their recessed
and/or hidden areas. Leave them all fully
immersed in the second basket with the
solution prepared above for the time required
(no less than 5 minutes).
•By using an hard bristle brush or any other
appropriate tool, carefully clean the extrusion
flange (24) and the small grid (25) and his
recessed and/or hidden areas. Pay attention
in particular to the gaskets sites and to the
rails where the gate (9) gets stuck. Leave
them all fully immersed in the second basket
with the solution prepared above for the time
required (no less than 5 minutes).
•By using the wet cloth previously immersed in
the sanitizing solution, carefully clean all the
ORs gaskets, the interlocking buffers (20),
the gate (9), the screws (12), (14) and (13),
the lid (3), the lid cap (3a) and the silicon cap.
Leave them all fully immersed in the second
basket with the solution prepared above for
the time required (no less than 5 minutes).
11

Publicidad

loading