Descargar Imprimir esta página

Johnson DYNAMO74 Manual De Instrucciones página 32

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
1. DIP switch
2. CT interface
3. Ethernet interface
1. Take the unit and remove the 4 screws on its fixing bracket (The unit is integrated with the fixing bracket and
needs to be disassembled first). Keep the screws and fixing bracket for subsequent use;
2. Remove the 6 fixing screws on the front shell and the rear shell, save the screws for subsequent use; Note:
Reference fig.1 for steps 1 and 2.
3. Open the front shell carefully. The front shell is connected to the unit body through a cable. Be careful not to
damage or break the cable.
Caution: After opening the front shell, visually inspect the inside. If the wiring terminal block or the fixed
component falls off the track, it can be installed back to the track by itself (reference fig. 2)
b
a
b
a
b
a. 4 x fix bracket fix screw
b. 6 x Front &back shell fixed screws
CONNECT ELECTRICAL WIRING
AC220V~240V 50/60Hz
Terminal
Button
RCD
1
2
PE N-IN
L-IN L-OUT
PE
CT
L
N
3
CT1: Supply grid
CT2: Solar energy
CP (Black or Orange)
PP (Grey or White)
PE (Yellow/green)
N (Blue)
L (Brown)
INSTALLATION
b
a
b
a
b
fig. 1
LILGi g HhTt
Power
management
-
CT1
1
2+
CT2
3 -
N-OUT
4+
PP CP
5 -
CT3
6+
PCB
Ethernet
Socket/
Connector
terminal
block
track
fixed
components
* The installation method 2 in the cable entry
manual is used for the back entry, and the bottom
installation method 1 is not applicable
fig. 2
9
Note: The charger must be
electrically protected by installing
externally a Miniature Circuit
Breaker (MCB) and a Residual
Current Circuit Breaker(RCCB).
MCB: Maximum value according to
the maximum output current of
the load point.
Reference SET THE DIP SWITCH.
RCCB: According to local regula-
tions, Type A or Type B.
Mounting hole: Φ6*35
The cable entry hole
24.5
(for mode 2)
140.2
Fixing
bracket
unit: mm
V.1

Publicidad