INSTALLATION INSTRUCTIONS
You need to set the corresponding position of the current DIP switch according to the min. wire size shown in
the chart and the rated current of the Circuit breaker (factory setting 32A). refer to the steps below.
Caution 1: The following operations must be powered off.
Caution 2: Incorrect setting DIP may cause hazards such as overheating or fire of the incoming wire.
1. Locate the position of the two-position DIP switch on the power supply board, like picture.
2. Setting the switch to the desired position:
WARNING: Electrical Power Switches must only be set by a qualified electrical installer. Incorrect setting may
lead to equipment damage and / or personal injury. The current rating must not exceed the supply rating.
NOTE:
when you set the DIP4 switch postion to on, both APP and OCPP can control the charger;
1.
when you set the DIP4 switch postion to off, only OCPP can control the charger.
2.
1. Check that this unit must be grounded (Earthed).
Make sure you are satisfied that the installation is complete and is in a safe condition.
2.
Switch ON the power, which it will cycle the red, blue and green lights to self-check and then enter the
3.
corresponding light indication. The unit and test in accordance with the current Electrical Wiring Regulations.
NOTE: Make sure this product has been installed in compliance with the
current Electrical Wiring Regulations.
SET THE DIP SWITCH
DIP switch
position
Current(A)
Min. wire size
(copper)
Circuit breaker
ON
DIP switch
1 2 3 4*
position
Earth
check
INSPECTION
ON
1 2
32
6mm²
or 10AWG
or 13AWG
40
(Amps)
ON
ON
DIP switch
3
3
Yes
No
15
ON
ON
1 2
1 2
16
13
2.5mm²
2mm²
1.5mm²
or 14AWG
or 15AWG
20
20
ON
position
4
APP and
CONTROL
Only OCPP
OCPP
ON
1 2
10
16
ON
4
V.1

Publicidad

loading