8.2
Troubles and causes of remote controller
Before asking for serving or repairing , check the following
points.
(see in table 2)
Symptoms
The fan speed can not be
changed.
The remote controller signal is
not transmitted even when
the ON/OFF button is pushed.
The TEMP. indicator does
not come on.
The indication on the display
disappears after a lapse of
time.
The TIMER ON indicator
goes off after a lapse of
certain time.
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pressed.
8.3
Malfunctions and malfunction code
If anything happens like the situation described below, please shut off the power supply of the unit
and contact with the custormer service center immediately.
NO.
N O .
1
Room temperature sensor check channel is abnormal.
1
2
Evaporator sensor checking channel is abnormal.(T2C)
3
Evaporator sensor checking channel is abnormal.(T2H)
2
4
EEprom malfunction.
5
Fan failure.
6
Protection against freezing
7
Excess water temperature protection
8
Water-level switch malfunction.
9
Not set models.
10
Indoor unit switch at long-range controller is dialed to OFF.
owner's manual
owner's manual
6
6
Causes
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
Check whether the batteries
in the remote controller are
exhausted.
Check whether the MODE
indicated on the display is
FAN ONLY
Check whether the timer
operation has come to an
end when the TIMER OFF
is indicated on the display.
Check whether the timer
operation is started when
the
TIMER ON
is indicated
on the display.
Check whether the signal
transmitter of the remote
controller is properly directed
to the infrared signal receiver
of the indoor unit when the
ON/OFF button is pressed.
M al f unc t i on
V.1
table 2
Solution
When the automatic mode is
selected, the air conditioner will
automatically change the fan
speed.
When dry operation is selected,
the air conditioner automatically
change the fan speed. The fan
speed can be selected during
"COOL" , "FAN ONLY",
and "HEAT"
The power supply is off.
The temperature cannot be set during
FAN mode.
The air conditioner operation will
stop up to the set time
Up to the set time, the
air conditioner will automatically
start and the appropriate
indicator will go off.
Directly transmit the signal transmitter of
the remote controller to the
infrared signal receiver of the
indoor unit, and then repeatly
push the ON/OFF button twice.
al ar m l amp
E2
E3
E4
E7
E8
P0
P1
EE
PF
----

Publicidad