Symptom 5: Dust comes out of the unit
When the unit is used for the first time in a long time.
This is because dust has gotten into the unit.
Symptom 6: The units can give off odours
The unit can absorb the smell of rooms, furniture, cigarettes,
etc., and then emit it again.
table 1
Symptoms
Unit does not start
Air flowing normally but
completely can't cooling
Units start or stop frequently
Low cooling effect
Low heating effect
8. TROUBLESHOOTING
8.1.
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
If the system does not properly operate except the above
mentioned cases or the above mentioned malfunctions is
evident, investigate the system according to the following
procedures. (see in table 1)
Causes
Power failure.
Power switch is off.
Fuse of power switch may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Temperature is not setted correctly.
Air or no concreting gas in the watering
circuit.
three-way valve is malfunction.
Voltage is too high or too low.
System circuit is blocked.
Temperature is not setted correctly.
Indoor unit heat exchanger is dirty.
The air filter is dirty.
Inlet/outlet of indoor units is blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Leakage of water .
Doors and windows not completely
closed.
Leakage of water.
V.1
Troubles and causes of air conditioner
The operation lamp is flashing rapidly (five times per second),
you disconnect the unit with the power and then connect the
unit with the power again after two or three minutes but the
lamps still flash.
Switch operations are erratic.
The fuse is blown frequently or the circuit breaker is tripped
frequently.
Foreign matter or water has fallen inside the air conditioner.
Water leaks from the indoor unit.
Solution
Wait for the comeback of power.
Switch on the power.
Replace the fuse.
Replace the batteries or check the
controller.
Set the temperature properly.
Vacuum .
Maintenance or change three-way
valve.
Install manostat.
Find reasons and solution.
Clean the heat exchanger.
Clean the air filter.
Eliminate all dirties and make air
smooth.
Close doors and windows.
Make curtains in order to shelter from
sunshine.
Reduce heat source.
AC cooling capacity reduces (normal).
Check leakage .
Use heating device.
Close doors and windows.
Check leakage.
owner's manual
5