VPA 47702052 11-2011
50113
8. Check reservoir: The fluid level (H) should have
dropped 1/4 in. (6-7mm).
9. If reservoir does not drop 1/4 in. (6-7mm), it may
be necessary to repeat Steps 1-7.
10. Run engine at 1500-2000 RPM to help start fluid
flow. For normal operation, run engine at idle.
11. If fluid is still not flowing from the reservoir, check
the following and correct as needed:
Check hoses for kinks and tight clamps.
There is a small vent hole in the reservoir
cap: Make sure it is not covered.
Check that solenoid opens when rocker
switch is on and key is on RUN.
Check fuse (PN 983966).
Check for power at switch.
Check connection to solenoid.
Check ground connection.
9